Technical Details

Specification H3M05551AE H4M080S1AE H5M125S1AE
Performance
Rating cooling capacity (W)5500800012000
Rating heating capacity (W)5800880013500
Rated power input (cooling) (W)138023503530
Rated power input (heating) (W)138020803100
EER (W/W)3.953.43.4
COP (W/W)4.24.24.35
AER (W·h)4.063.784.02
ACOP (W·h)4.004.224.28
Minimum cooling capacity (W)160029003600
Maximum cooling capacity (W)6600950013800
Working temp. - Cooling (°C)-10~46-10~46-10~46
Working temp. - Heating (°C)-15~24-15~24-15~24
Electrical
Minimum power input (W)550550550
Maximum power input (W)250035005200
Power source1PH, 220–240V~, 50/60Hz
Max running current (A)10.815.523.0
Starting current (A)555
Fuse size (A)252530
Outdoor Unit
Dimensions (WxDxH, mm)890×340×700890×340×700950×370×965
Sound power level (dB[A])646673
Sound pressure level (dB[A])515558
Weight Net/Shipping (kg)50

Find a Bonaire Dealer Near You

Loading store locator ...