Specifications


Model
IndoorB007HDB009HDB012HDB015HDB019HD


OutdoorB007RSB009RSB012RSB015RSB019RT
Capacity       
Rated capacityCoolingkW7.18.91214.718.7
 HeatingkW7.99.312.215.319.3
Power inputCoolingkW2.93.14.45.36.7
 HeatingkW2.73.14.35.36.1
Features       
RF Wireless Remote Controller 
Soft Starter  
Super Hydrophilic Anti Corrosion Fins 
LV Wall Mounted Controller 
Reverse Cycle 
7-Day Multi-schedule Programming 
Soft Heat Mode 
Multi-function Defrost Cycles 
Auto-Changeover Function 
Economy Mode 
Zone Control 
Auto Restart* 
Performance       
Rated Indoor Airflow L/S4505407508501050
Rated Static Pressure Pa140140140140160
EERCoolingW/W2.452.872.732.772.79
COPHeatingW/W2.9332.842.893.16
Electrical       
Power Supply Ø/V/Hz1/240/501/240/501/240/501/240/503/415/50
Running CurrentCoolingA13.414.420.425.112.8
 HeatingA12.514.419.925.112.1
Compressor Type  RotaryScrollScrollScrollScroll
Outdoor SoundPressure(dB(A)±2)5256565863
Level @ 1m       
Installation & Dimensions       
DimensionsIndoorHxWxD mm381x946x510401x1181x510401x1301x510 
 OutdoorHxWxD mm860x870x340960x970x365              1260x970x365         1465x970x365
WeightIndoorKg3939464653
 OutdoorKg609297103131
Duct ConnectionSupplyWxH mm246x251721x281721x295
FlangesReturnWxH mm716x292951x3421071x342
Refrigerant  R22R22R22R22R22
Pipe ConnectionLiquidmm9.539.539.539.539.53
SizesGasmm15.8819.0519.0519.0519.05
Connection Type  FlareFlareFlareFlareFlare
Max. Pipe Length M2025252525
Max. Height Difference M1515151515
Precharged Length M1010101010
Drain Connection Size OD Ø mm2525252525
Outdoor Operating RangeCooling15°C ~ 46°C
 Heating(-5°C) ~ 24°C

*The ‘Auto Restart’ feature is only available with the ‘RF Remote Control’ system kit.

Notes:

1. Rated Cooling Capacities are based on an indoor temp 27°C DB / 19°C WB and an outdoor temp 35°C DB and 24°C WB in accordance with AS

NZS3823.1.2, at the rated airflows listed above.

2. Rated Heating Capacities are based on an indoor temp 21°C DB and an outdoor temp 7°C DB / 6°C WB in accordance with AS/NZS3823.1.2, at the

rated airflows listed above.

3. All capacities are net and include 7.5m of interconnecting pipe, with zero level difference.

4. Outdoor sound pressure measurement is taken inside and anechoic chamber at a distance of 1M directly in front. Sound levels may vary due to

different installation locations and environments.

5. Running Current is at rated conditions in accordance with AS/NZS3823.1.2. This does not include start-up or variations in power supply and load conditions.